Gasoline
Generators |
| |
|
|
Model
: GG950 |
|
. |
|

|
■
Compact and portable power
for emergency
and home standby use.
■
4.2L fuel tank capacity ensures 5.8
hour-running without refueling.
■
2.0HP 2-stroke gasoline engine.
■
Overload protection for safe
running. |
|
|
|

|
|
|
| AC
Frequency(Hz) |
|
50Hz |
| AC
Con.Output (W) |
|
220;230;240; |
| AC
Max.Output (W) |
|
650W |
| Max.AC
Output |
|
720W |
| Power
Factor |
|
1.0 |
| DC
Output (W) |
|
12V/5.8A |
| Engine |
|
UP65 |
| Type |
|
OHV
2-stroke; air-cooled;
single-cylinder |
| Displacement(cc) |
|
63 |
| Starting
System |
|
Recoil |
| Lubrication
oil |
|
Pre-mixed
Fuel(50:1) |
| Max.Output(hp/rpm) |
|
2.0/3000 |
| Fuel
Tank Capacity(l) |
|
4.2 |
| Continuous
Work(h) |
|
5.8 |
| Noise
Level LwA dB(A) |
|
90 |
| Dim(mm) |
|
365X310X370 |
| Gross
Weight(kg) |
|
18.5 |
|
|
|
. |
|
Model
: GG1300
|
|
. |
|

|
■
Compact and
portable power for emergency and home
standby use.
■ 6L fuel tank capacity ensures 6
hour-running without refueling.
■ 2.4HP max output 4-stroke gasoline
engine. ■
Standard configuration of
voltmeter.
■ Engine
confirms to EPA, CARB, EC-II.s |
|
. |
|

|
|
|
| AC
Frequency (Hz) |
|
50Hz |
| AC
Output voltage(V) |
|
220;230;240; |
| Rated
AC Output |
|
0.9kW |
| Max.AC
Output |
|
1.1kW |
| Power
Factor |
|
1.0 |
| DC
Output |
|
12V/5.8A |
| Engine |
|
UP154 |
| Type |
|
4-stroke;
air-cooled OHV,Gasoline Engine |
| Displacement(cc) |
|
87 |
| Starting
System |
|
Recoil |
| Lubrication
oil |
|
SAE
10W/30 |
| Max.Output(hp/rpm) |
|
2.4/3000 |
| Fuel
Tank Capacity(l) |
|
6.0 |
| Continuous
Work(h) |
|
6 |
| Noise
Level LwA dB(A) |
|
90 |
| Dim(mm) |
|
467X365X422 |
| Gross
Weight(kg) |
|
28 |
|
|
|
|
|
Model
: GG2700
|
|
. |
|

|
■
Large control panel with double
voltage for widely using.
■ 15L
fuel tank enables 10-hour continuous
running.
■ 5.5HP
max output gasoline engine.
■ Hydraulic-Magnetic
circuit breaker.
■ Large
muffler for quiet operation.
■ Engine
confirms to EPA, CARB |
|
. |
|


|
|
|
| AC
Frequency (Hz) |
|
60Hz |
| AC
Output voltage(V) |
|
110,120,110/220;120/240 |
| Rated
AC Output |
|
2.3kW |
| Max.AC
Output |
|
2.7kW |
| Power
Factor |
|
1.0 |
| DC
Output |
|
12V/5.8A |
| Engine |
|
UP168 |
| Type |
|
4-stroke;
air-cooled OHV,Gasoline Engine |
| Displacement(cc) |
|
196 |
| Starting
System |
|
Recoil |
| Lubrication
oil |
|
SAE
10W/30 |
| Max.Output(hp/rpm) |
|
5.5/3600 |
| Fuel
Tank Capacity(l) |
|
15 |
| Continuous
Work(h) |
|
10 |
| Noise
Level LwA dB(A) |
|
90 |
| Dim(mm) |
|
590X440X500 |
| Gross
Weight(kg) |
|
45 |
|
|
|
|
|
|
|
Model
: GG3300 |
|
. |
|

|
■
Large muffler for quiet operation.
■
15L fuel tank enables 11-hour
continuous running.
■
6.5HP max output gasoline engine.
■
Hydraulic-Magnetic circuit breaker.
■
Engine confirms to EPA, CARB,
EC-II. |
|
|
|

|
|
|
| AC
Frequency (Hz) |
|
50Hz |
| AC
Output voltage(V) |
|
220;230;240;115/230 |
| Rated
AC Output |
|
2.4kW |
| Max.AC
Output |
|
2.6kW |
| Power
Factor |
|
1.0 |
| DC
Output |
|
12V/8.3A |
| Engine |
|
UP168 |
| Type |
|
4-stroke
OHV; Air-cooled; Gasoline
Engine |
| Displacement(cc) |
|
196 |
| Starting
System |
|
Recoil |
| Lubrication
oil |
|
SAE
10W/30 |
| Max.Output(hp/rpm) |
|
6.5/3000 |
| Fuel
Tank Capacity(l) |
|
15 |
| Continuous
Work(h) |
|
11 |
| Noise
Level LwA dB(A) |
|
90 |
| Dim(mm) |
|
607X445X522 |
| Gross
Weight(kg) |
|
46.5 |
|
|
|
. |
|
Model
: GG7200 |
|
. |
|

|
■
Oil alert system with automatic
engine shut-off.
■ 13HP
gasoline engine equipped.
■ 25L
fuel tank enables 10-hour running.
■ Large
muffler for quiet operation.
■ Engine
confirms to EPA, CARB, EC-II. |
|
|
|

|
|
|
| AC
Frequency (Hz) |
|
50Hz |
| AC
Output voltage(V) |
|
220;230;240;115/230 |
| Rated
AC Output |
|
5.0kW |
| Max.AC
Output |
|
6.0kW |
| Power
Factor |
|
1.0 |
| DC
Output |
|
12V/8.3A |
| Engine |
|
UP188 |
| Type |
|
OHV
4-Stroke; Air-cooled;
Single-Cylinder |
| Displacement(cc) |
|
389 |
| Starting
System |
|
Recoil/Electric |
| Lubrication
oil |
|
SAE
10W/30 |
| Max.Output(hp/rpm) |
|
13.0/3000 |
| Fuel
Tank Capacity(l) |
|
25 |
| Continuous
Work(h) |
|
10 |
| Noise
Level LwA dB(A) |
|
96 |
| Dim(mm) |
|
697X525X562 |
| Gross
Weight(kg) |
|
82 |
|
|
|
|
|
Diesel
Generators |
| |
|
|
Model
: DG2300-E |
|
. |
|

|
■
Advanced AVR offers over-voltage,
overheated and overload protection for the
generator.
■ Frame
designed for better protection.
■ 4.7HP
4-stroke air-cooled direct injection
diesel
■ 11.5L
fuel tank ensures 14 hours of continuous
running.
■ Hydraulic-Magnetic
CB for overload protection.
■ Electric
start standard equipped. |
|
|
|

|
|
|
| AC
Frequency (Hz) |
|
50Hz |
| AC
Output voltage(V) |
|
220;230;240;115/230 |
| Rated
AC Output |
|
1.7kW |
| Max.AC
Output |
|
2.0kW |
| Power
Factor |
|
1.0 |
| DC
Output |
|
12V/8.3A |
| Engine |
|
UD170 |
| Type |
|
Single-Cylinder,4-Stroke,
Air-Cooled Diesel Engine |
| Displacement(cc) |
|
219 |
| Starting
System |
|
Electric
Starter |
| Lubrication
oil |
|
SAE
10W/30 |
| Max.Output(hp/rpm) |
|
4.7/3000 |
| Fuel
Tank Capacity(l) |
|
11.5 |
| Continuous
Work(h) |
|
14 |
| Noise
Level LwA dB(A) |
|
96 |
| Dim(mm) |
|
635X465X545 |
| Gross
Weight(kg) |
|
67 |
|
|
|
. |
| |
|
|
Model
: DG5500-E |
|
. |
|

|
■
10HP 4-stroke air-cooled
direct injection diesel engine.
■ 11.5L
fuel tank ensures 6.5 hours of continuous
running.
■
Brushless alternator for easy
maintenance.
■
Hydraulic-Magnetic CB for overload
protection.
■
Engine confirms to EPA, CARB,
EC-II. |
|
|
|

|
|
|
| AC
Frequency (Hz) |
|
50Hz |
| AC
Output voltage(V) |
|
220;230;240;115/230 |
| Rated
AC Output |
|
4.5kW |
| Max.AC
Output |
|
5.0kW |
| Power
Factor |
|
1.0 |
| DC
Output |
|
12V/8.3A |
| Engine |
|
UD186 |
| Type |
|
Single-Cylinder,4-Stroke,
Air-Cooled Diesel Engine |
| Displacement(cc) |
|
418 |
| Starting
System |
|
Electric
Starter |
| Lubrication
oil |
|
SAE
10W/30 |
| Max.Output(hp/rpm) |
|
10/3000 |
| Fuel
Tank Capacity(l) |
|
11.5 |
| Continuous
Work(h) |
|
6.5 |
| Noise
Level LwA dB(A) |
|
98 |
| Dim(mm) |
|
727X495X597 |
| Gross
Weight(kg) |
|
98 |
|
|
|
. |
|
Model
: GG5500SE |
|
. |
|

|
Advanced
AVR offers over-voltage, overheated and
overload protection for the generator.
■ Low
noise construction and double mufflers for
quiet operation.
■ 10HP
diesel engine.
■ 16L
fuel tank enables 7.3-hour running.
■ Wheels
for easy moving.
■ Standard
equipment of electric start and battery.
|
|
|
|
|
|
|
| AC
Frequency (Hz) |
|
50Hz |
| AC
Output voltage(V) |
|
220;230;240;115/230 |
| Rated
AC Output |
|
4.2kVA |
| Max.
AC Output |
|
4.6kVA |
| Power
Factor |
|
1.0 |
| DC
Output |
|
12V/8.3A |
| Engine |
|
UD186 |
| Type |
|
Single-Cylinde,
4-Stroke, Air - Cooled Diesel
Engine |
| Displacement
(cc) |
|
418 |
| Starting
system |
|
Electric
Starter |
| Max.
Output(hp/rpm) |
|
10/3000 |
| Fuel
Tank Capacity(L) |
|
16 |
| Continuous
Work(H) |
|
7.3 |
| Noise
level LwA dB(A) |
|
89 |
| Dim(mm) |
|
955x575x865 |
| Gross
Weight (kg) |
|
185 |
|
|
|
Model
: DG6000-E |
|
. |
|

|
■
Advanced AVR offers over-voltage,
overheated and overload protection for the
generator.
■ Frame
designed for better protection.
■ 10HP
4-stroke air-cooled direct injection
diesel engine.
■ 11.5L
fuel tank ensures 6.5 hours of continuous
running.
■ Hydraulic-Magnetic
CB for overload protection.
■ Electric
start standard equipped.
|
|
|
|

|
|
|
| AC
Frequency (Hz) |
|
50Hz |
| AC
Output voltage(V) |
|
220;230;240;115/230 |
| Rated
AC Output |
|
4.5kVA |
| Max.
AC Output |
|
5.0kVA |
| Power
Factor |
|
1.0 |
| DC
Output |
|
12V/8.3A |
| Engine |
|
UD186 |
| Type |
|
Single-Cylinde,
4-Stroke, Air - Cooled Diesel
Engine |
| Displacement
(cc) |
|
418 |
| Starting
system |
|
Electric
Starter |
| Max.
Output(hp/rpm) |
|
10/3000 |
| Lubrication
Oil |
|
SAE
10W/30 |
| Fuel
Tank Capacity(L) |
|
11.5 |
| Continuous
Work(H) |
|
6.5 |
| Noise
level LwA dB(A) |
|
96 |
| Dim(mm) |
|
727X495X597 |
| Gross
Weight (kg) |
|
98 |
|
|